Room temperature transmitter

The temperature transmitter serie TTI measures the room temperature by sensor and converts the value into a linear output signal 0...10 V DC o 4...20 mA..

download datasheetpdf icon  cod. TTI

Outdoor temperature transmitter

The temperature transmitter serie TTO measures the outdoor temperature by a sensor and converts the value into a linear output signal 0...10 V DC o 4...20 mA. The temperature sensor is protected against contamination by a nickeled pipe.

download datasheetpdf icon  cod. TTO

Duct / Screw-in temperature transmitter

The temperature transmitter serie TTD / TTS measures the duct temperature and screw-in by a sensor and converts the value into a linear output signal 0...10 V DC o 4...20 mA. The temperature sensor is protected against contamination by a nickeled pipe.

download datasheetpdf icon  cod. TTD / TTS

Room humidity and temperature transmitter

The temperature/humidity transmitter serie TTHI measures the room temperature and humidity by a capacitive humidity sensor and converts the value into a linear output signal 0...10 V DC. The humidity and temperature sensor is protected against contamination by a sinter filter.

download datasheetpdf icon  cod. TTHI

Outdoor humidity and temperature transmitter

The temperature/humidity transmitter serie TTHO measures the outdoor temperature and humidity by a capacitive humidity sensor and converts the value into a linear output signal 0...10 V DC o 4...20 mA. The humidity and temperature sensor is protected against contamination by a screw sinter filter.

download datasheetpdf icon  cod. TTHO

Duct humidity and temperature transmitter

The temperature/humidity transmitter serie TTHD measures the duct temperature and humidity by a capacitive humidity sensor and converts the value into a linear output signal 0...10 V DC o 4...20 mA. The humidity and temperature sensor is protected against contamination by a screw sinter filter.

download datasheetpdf icon  cod. TTHD

Airflow and velocity transducer

The airflow and velocity transducer series FSE is design to control the air flow into air duct in HVAC systems and in VAV applications.

download datasheet pdf icon  cod. FSE

 

Air differential pressure transmitter

The differential pressure transmitter serie PTM is used to measure differential pressure, overpressure and vacuum of gaseous, nonaggressive media. It provides 2 pressure ranges and 2 output signals, which are selectable by jumper. Possible fields of application are building automation and air conditioning systems, overpressure measurement in clean rooms and laboratories, measurement of constant pressure in VAV applications, dynamic filter and ventilator monitoring.

download datasheetpdf icon  cod. PTM

Air differential pressure transmitter

The differential pressure transmitters serie PTQ is used to measure differential pressure, overpressure and vacuum of gaseous, nonaggressive media. It provides 8 pressure ranges and 2 output signals, which are easily selectable by jumper or rotary selector switch. Possible fields of application are building automation and air conditioning systems, overpressure measurement in clean rooms and laboratories, measurement of constant pressure in VAV applications, dynamic filter and ventilator monitoring.

download datasheetpdf icon  cod. PTQ

Air differential pressure transmitter IP65

The differential pressure transmitter serie PTG is used to measure differential pressure, overpressure and vacuum of gaseous, nonaggressive media. It provides 2 pressure ranges and 2 output signals, which are selectable by jumper. Possible fields of application are building automation and air conditioning systems, overpressure measurement in clean rooms and laboratories, measurement of constant pressure in VAV applications, dynamic filter and ventilator monitoring.

download datasheetpdf icon  cod. PTG

Differential pressure transmitter

 

The differential pressure transmitters of the PTR series are used to measure differential pressure, overpressure and vacuum. They provide one adjustable pressure range and one output signal. Monitoring of gaseous, non-aggressive media. Possible usage areas are: Building automation, air conditioning systems and clean room monitoring, valve and flap control, filter, ventilator and blower monitoring, control of air flows.

download datasheetpdf icon  cod. PTR

 

Relative pressure transmitter

The relative pressure transmitter PTD series with ceramic measuring cell is used to measure relative pressures of non-aggressive media. Possible fields of application are building automation, industrial, pneumatic and hydraulic sectors. The standard series covers various measurement ranges (see schedule) with linear output signals 4...20 mA or 0...10 V DC. The resistant stainless steel case is available with two connectors and has an IP65 protection class.

download datasheetpdf icon  cod. PTD

Volume flow transmitter

The transmitters of the PTV series are used to measure volume flow, differential pressure, overpressure and vacuum. A jumperThe transmitters of the PTV series are used to measure volume flow, differential pressure, overpressure and vacuum. A jumperenables switching between volume flow and pressure measurement. Monitoring of gaseous, non-combustible and non-aggressivemedia. Possible usage areas are: Building automation and air conditioning systems, overpressure measurement in clean rooms and laboratories, measurement of constant pressure in VAV applications, dynamic filter and ventilator monitoring.

download datasheetpdf icon  cod. PTV

 

Light sensor

The light sensor detects the light intensity and converts the value into a linear analogue signal with 4 selectable ranges. Available relay output.

download datasheetpdf icon  cod. LUX

CO2 room sensor

The SAC CO2 sensor measures air quality through the presence of carbon dioxide in air ducts in the range between 0...2000 or 0...5000 ppm. The measurement of CO2 concentration happens through a NDIR sensor that operates on an infrared basis and which compensates the presence of any impurity. The product can be provided with humidity or humidity/temperature sensor. Output 0...10 V DC or 4...20 mA outputs.

download datasheetpdf icon  cod. SAC

CO2 duct sensor

The SDC CO2 sensor measures air quality through the presence of carbon dioxide in air ducts in the range between 0...2000 or 0...5000 ppm. The measurement of CO2 concentration happens through a NDIR sensor that operates on an infrared basis and which compensates the presence of any impurity. The product can be provided with humidity or humidity/temperature sensor. Output 0 ... 10 V DC or 4 ... 20 mA outputs.

scarica scheda tecnicapdf icon  cod. SDC

Room air quality sensor

The air quality sensor serie SAV for mixed gases (VOC) measures the air quality from 0...2000 ppm referring to the calibration gas. The sensors with provided by linear output signal 0...10 V DC or 4...20 mA.

download datasheetpdf icon  cod. SAV

Air quality duct sensor

The SDV sensor measures air quality in air ducts in the range between 0...2000 ppm. The product can be provided with humidity or humidity/temperature sensor. Output 0 ... 10 V DC or 4 ... 20 mA outputs.

download datasheetpdf icon  cod. SDV

CO2 and air quality duct sensor

The SDCV sensor measures air quality and the presence of carbon dioxide in air ducts in the range between 0...2000 or 0...5000 ppm. The measurement of CO2 concentration happens through a NDIR sensor that operates on an infrared basis and which compensates the presence of any impurity. The product can be provided with humidity or humidity/temperature sensor. Output 0...10 V DC or 4...20 mA outputs.

download datasheetpdf icon  cod. SDCV